What's So Amazing
- Quick Cure Straw Foam provides an economical, quick, no-fuss way of filling small cracks and gaps with the great sealing and insulating properties of expanding polyurethane foam.
- Quick Cure Straw Foam seals around plumbing, ventilation outlets, electrical junctions or anywhere you need a fast, air sealing barrier to moisture and drafts. Its closed-cell structure provides a permanent insulation solution with RV component materials such as wood, metals and plastics, creating effective barriers to energy loss.
- It has a long shelf life of 24 months. Just take it off the shelf and spray. It can be partially used, stored and restarted later.
- Straw and adapter included. No spray gun needed.
- It has no ozone depleting chemicals and is Energy Star rated as environmentally friendly.
- Insulating R-Value is 4.9 per inch of thickness.
- Approved fireblock penetration sealant.
Shopping Cart
Factory Friendly
Seal Design and Dicor Corporation focus on the people and companies that use our products. This includes products, support and services that help improve the production process.
- Straw and adapter included. No spray gun needed.
- It has a long shelf life of 24 months. Just take it off the shelf and spray. It can be partially used, stored and restarted later.
Technical Data
Density - 1.75+/-.25 lbs./cu.ft.
R Value - 4.9 per inch thickness
Max. Service Temp for Cured Foam - 240ºF (116ºC)
Shelf Life - 12 months
Flame Spread - 10
Smoke Developed - 15
ICC-ESR-1926
Applicable Standards
ASTM E-96 Water Vapor Transmission
ASTM C-273 Shear Strength
ASTM C-273 Shear Strain
ASTM C-518 R-Value
ASTM E-814 Firestop Penetration
ASTM C-1536 Yield
ASTM D-1621 Compressive Strength
ASTM D-1622 Density
ASTM D-1623 Tensile Strength
ASTM D-2856 Closed Cell Content
UL 1715 Fire Test
UPB26-3 Corner Room Fire Test
Approvals/Certifications
International Building Code
International Residential Code
BOCA National Building Code
1999 Standard Building Code
1997 Standard Building Code
ICC-Evaluation Services
California Bureau of Home Furnishings and Insulation
Underwriters Laboratories Classified Caulking & Sealants
Limitations
Do not expose to temperatures above 240° F (116° C), open flames or sparks
Not for exposure to ultraviolet light
Chemicals must be 50°-100° F (10°-38° C) prior to application
Do not store in temperatures above 120° F (49° C)
Always refer to local building code regulations
Do not leave product exposed; cover with approved facings
Propellant in 12 & 24 ounce straw foam is flammable; read MSDS and do not use near high heat, sparks or open flame
Not a fire stop material
Physical/Chemical Properties
Click here for table. Test data available upon request.
Warranty
Applications
Specs
Yield in Linear Feet
| 12 oz. can | 1/4-inch bead | 918 ft |
| 3/8-inch bead | 408 ft | |
| 24 oz. can | 1/4-inch bead | 1,805 ft |
| 3/8-inch bead | 818 ft |
Measuring
Installation
Always refer to local building codes prior to application of Touch-N-Seal® foam sealants.
The Touch-N-Seal Quick Cure one-component expanding foam sealant can be applied to and will adhere to almost any traditional construct surfaces including wood, masonry, insulating foam boards, metal, plastics and sheetrock. Surfaces to receive Touch-N-Seal foam sealants must be dry, clean and free of dust, dirt, grease and other substances that may inhibit proper adhesion. For best results apply Touch-N-Seal Quick Cure expanding foam sealant when surface and ambient temperatures are between 60°-100° F (16°-38° C). Temperature of chemical contents must be between 50°-100° F (10°-38° C) before dispensing. Use all chemical contents within 30 days of initial dispensing.
Always wear proper personal protective equipment, including gloves, clothing and eyewear. Use in well-ventilated area.
Shelf Life
12 months in unopened container when stored between 60°-90° F (16°-32° C), in a dry, well-ventilated area.
Storage & Disposal
Keep containers tightly closed in a cool, well-ventilated area. Ideal storage temperature is 60°-90° F (16°-32° C). Storage above 90° F (32° C) will reduce shelf life. Do not store at temperatures greater than 120° F (49° C). Do not expose containers to conditions that may damage, puncture, or burst the containers. Dispose of leftover material/containers in accordance with Federal, state and local regulations. See Material Safety Data Sheet for more information.